Working with PWSCF#
PWSCF Workflows#
Allowed inflowing dependencies#
TBD
Available outflowing dependencies#
TBD
PWSCF Input#
Generating input#
TBD
Reading and manipulating input#
TBD
Writing input#
TBD
PWSCF Data Analysis#
Nexus reads the results of a completed Quantum ESPRESSO pw.x calculation
with a PwscfAnalyzer object. Its query functions
provide a consistent interface to structures, energies, k-points, electronic
data, forces, and stress. When modern Quantum ESPRESSO XML and text output
are both available, modern XML is preferred and text output fills unavailable
quantities. Some information, such as an ionic trajectory, is unique to text
output.
The following sections show how to load an analyzer and retrieve physical
quantities. A query normally returns None if relevant data was not written
or could not be parsed. It raises an exception if analysis was not performed,
the quantity is inapplicable to the detected run type, or an invalid unit is
requested.
Note: PWSCF and RMG analyzers share the exact same access patterns and return types for obtaining physical quantities.
Loading data from a simulation#
For a calculation created with generate_pwscf, pass the
simulation object to analyze_output. The factory loads a saved
analyzer image when present; otherwise it constructs and analyzes an analyzer.
from nexus import analyze_output
scf = generate_pwscf(
...
)
ao = analyze_output(scf)
ao is a PwscfAnalyzer object. This is convenient in a Nexus workflow
because the simulation supplies all the information needed to perform the analysis.
Reading data directly#
Output can also be analyzed without a simulation object. Give
analyze_output the code name and any known input, text-output, or modern
XML paths. Using explicit file names is recommended (see
File selection and strict parsing for alternatives).
from nexus import analyze_output
ao = analyze_output(
'pwscf',
input = 'scf.in',
outfile = 'scf.out',
path = './scf_run',
)
# or with complete paths:
ao = analyze_output(
'pwscf',
input = './scf_run/scf.in',
outfile = './scf_run/scf.out',
)
The analyzer discovers modern Quantum ESPRESSO XML in the calculation directory and reads it automatically when present.
Accessing physical quantities#
The query methods return final values, rather than the histories printed during
iterative calculations. Scalar quantities are Python float or bool
objects; array quantities are NumPy float arrays; and structure queries
return Structure objects. Use the units argument where
applicable.
Supported run types and quantities#
The table lists data ordinarily produced by each major PWSCF run type. Actual
availability also depends on PWSCF printing options and successful parsing.
Here, common data means initial_structure, kpoints, and kweights;
electronic data means eigenvalues, occupations, Ef, Evbm,
Ecbm, band_gap, and fractional_occs.
Run type |
Quantities ordinarily available |
Not ordinarily applicable |
|---|---|---|
|
Common data, |
|
|
Common data, |
|
|
Common data and |
|
|
Common data, |
None of the listed query groups. |
|
The same data as |
None of the listed query groups. |
|
Common data, |
No query group solely because it is a dynamics run. |
Checking and requiring quantities#
Use available to check whether all named
quantities are accessible. It returns a single Boolean and does not initiate
additional parsing.
electronic_data = ao.available('Ef','eigenvalues','occupations')
print(electronic_data)
True
Use require when downstream work cannot
continue without a quantity. A later query for an unavailable required
quantity raises an exception rather than returning None.
print('Unavailable quantity:')
print('Energy =',[ao.energy()])
ao.require('energy','forces')
print('\nNow required:')
E = ao.energy()
Unavailable quantity:
Energy = [None]
Now required:
RuntimeError: required PWSCF quantity "energy" is not available
Common structure and k-point data#
initial_structure() returns a Structure with axes shaped (3, 3)
and pos shaped (natoms, 3). Its default length unit is Angstrom; use
units='B' for bohr.
structure = ao.initial_structure()
print('cell axes:')
print(structure.axes)
print('\natomic positions:')
print(structure.pos)
cell axes:
[[2.500 0.000 0.000]
[0.000 2.500 0.000]
[0.000 0.000 2.500]]
atomic positions:
[[0.000 0.000 0.000]
[1.250 1.250 1.250]]
kpoints() returns Cartesian reciprocal coordinates as a float array of
shape (nkpoints, 3). Its default unit is inverse bohr; use units='A'
for inverse Angstrom.
kpoints = ao.kpoints(units = 'A')
print(kpoints[:3])
[[ 0.000 0.000 0.000]
[ 0.628 0.000 0.000]
[ 0.000 0.628 0.000]]
kweights() returns the dimensionless integration weights as a float array
of shape (nkpoints,).
kweights = ao.kweights()
print(kweights)
[0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125]
Energy and electronic quantities#
energy() returns the final total energy as a Python float. The
default is Hartree; 'eV' and 'Ry' are also accepted.
energy = ao.energy(units = 'eV')
print(f'E = {energy:.3f} eV')
E = -129.342 eV
eigenvalues() returns a float array in eV by default, shaped
(nkpoints, nbands) for non-spin calculations or
(nkpoints, 2, nbands) for collinear spin calculations.
eigenvalues = ao.eigenvalues()
print(eigenvalues[0, :6])
[-15.382 -8.437 -1.928 2.714 6.183 9.762]
occupations() returns a dimensionless float array with the same shape as
eigenvalues().
occupations = ao.occupations()
print(occupations[0, :6])
[1.000 1.000 1.000 0.000 0.000 0.000]
Ef(), Evbm(), Ecbm(), and band_gap() return Python float
values in eV by default: the Fermi energy, valence maximum, conduction
minimum, and fundamental gap. Each accepts 'eV', 'Ha', or 'Ry'.
fermi_energy = ao.Ef()
vbm = ao.Evbm()
cbm = ao.Ecbm()
band_gap = ao.band_gap()
print(fermi_energy, vbm, cbm, band_gap)
5.931 4.802 6.427 1.625
fractional_occs() returns a Python bool indicating whether an
occupation is neither empty nor full within a default tolerance of 1e-3.
metallic = ao.fractional_occs(tol = 1e-4)
print(metallic)
False
Final structure, forces, and stress#
relaxed_structure() returns the final Structure for a relaxation or
molecular-dynamics calculation. Its axes and positions have the same shapes
as the initial structure.
relaxed_structure = ao.relaxed_structure(units = 'A')
print(relaxed_structure.pos)
[[0.000 0.000 0.000]
[1.247 1.247 1.247]]
forces() returns final Cartesian ionic forces as a float array of shape
(natoms, 3). The default unit is eV/Angstrom; 'Ry/B' and 'Ha/B'
are also accepted.
forces = ao.forces(units = 'eV/A')
print(forces)
[[-0.003 0.000 0.000]
[ 0.003 0.000 0.000]]
stress() returns the final stress tensor as a float array of shape
(3, 3). The default is GPa; it also accepts 'Pa', 'bar',
'kbar', 'Mbar', 'atm', 'eV/A^3', 'Ha/Bohr^3', and
'Ry/Bohr^3'.
stress = ao.stress(units = 'GPa')
print(stress)
[[ 0.010 0.000 0.000]
[ 0.000 0.012 0.000]
[ 0.000 0.000 0.014]]
pressure() returns the final hydrostatic pressure as a Python float.
It accepts the same units as stress() and uses GPa by default.
pressure = ao.pressure(units = 'GPa')
print(f'P = {pressure:.3f} GPa')
P = 0.012 GPa
File selection and strict parsing#
PWSCF results can be obtained from modern Quantum ESPRESSO schema XML, text
output, or both. By default, read_all=True reads every available source.
Modern XML values take precedence in physical-quantity queries, with text
output supplying values absent from XML. Legacy data-file.xml is retained
for separate inspection but is not used by these queries.
The direct forms below show how analyze_output identifies the
calculation location and chooses candidate XML and text-output files. The
keyword arguments shown after path are PWSCF-analyzer arguments.
ao = analyze_output(
'pwscf',
path = './scf_run',
strict = True,
)
With only directory path provided (no input or output filenames), Nexus searches
the directory for one *.out file and searches for one modern schema XML file
named data-file-schema.xml within a *.save directory. It checks both a
*.save directory directly inside the calculation directory and one level
below it.
ao = analyze_output(
'pwscf',
input = 'scf.in',
outfile = 'scf.out',
path = './scf_run',
strict = True,
)
An explicit outfile selects that text file directly. An explicit
input file is also parsed. When its CONTROL section specifies prefix
and outdir, those values identify the modern XML file at
outdir/prefix.save/data-file-schema.xml. This input-derived location takes
precedence over the directory search.
ao = analyze_output(
'pwscf',
input = './scf_run/scf.in',
read_all = False,
strict = True,
)
Passing an input-file path enables input-guided XML discovery. With
read_all=False and no required quantities, successfully parsed XML ends
the output-reading process.
ao = analyze_output(
'pwscf',
outfile = './scf_run/scf.out',
strict = True,
)
Passing a text-output path selects that file directly. No input file is
assumed, so modern XML discovery uses the directory search rather than
input-derived prefix and outdir values. An explicit xmlfile may be
provided when XML discovery is unnecessary or ambiguous.
With strict=True, explicitly supplied files are required to exist when
analysis begins. If neither xmlfile nor outfile is supplied, at least
one discoverable modern XML or text-output file must exist. A supplied input
file is also required. If discovery finds more than one candidate of a file
type, strict parsing raises an ambiguity error rather than choosing one
arbitrarily.
Set strict=False to inspect an incomplete directory without file-discovery
errors. Missing files are skipped. An ambiguous search is likewise treated
as unavailable and is not parsed. Applicable query functions then return
None when their data was not found, while any successfully parsed data
remains accessible.
ao = analyze_output(
'pwscf',
path = './interrupted_scf',
strict = False,
)
Modern XML is always parsed before text output. With read_all=True, text
output is parsed as well so that log-only data is available. With
read_all=False, text output is parsed only when one or more quantities in
the constructor’s required set remain unavailable after XML parsing. If
that set is empty, text output is skipped. Regardless of file selection, a
successfully parsed value remains accessible even when unusual for the
reconciled calculation type.