Working with RMG#
RMG Workflows#
Allowed inflowing dependencies#
TBD
Available outflowing dependencies#
TBD
RMG Input#
Generating input#
TBD
Reading and manipulating input#
TBD
Writing input#
TBD
RMG Data Analysis#
Nexus reads the results of a completed RMG calculation with an
RmgAnalyzer object. Its query functions provide a
consistent interface to structures, energies, k-points, electronic data,
forces, and stress. RMG data analysis uses the calculation log output.
The following sections show how to load an analyzer and retrieve physical
quantities. A query normally returns None if relevant data was not written
or could not be parsed. It raises an exception if analysis was not performed,
the quantity is inapplicable to the detected run type, or an invalid unit is
requested.
RMG follows the same physical-quantity access patterns and return types shown for PWSCF data analysis.
Loading data from a simulation#
For a calculation created with generate_rmg, pass the
simulation object to analyze_output. The factory loads a saved
analyzer image when present; otherwise it constructs and analyzes an analyzer.
from nexus import analyze_output
scf = generate_rmg(
...
)
ao = analyze_output(scf)
ao is an RmgAnalyzer object. This is convenient in a Nexus workflow
because the simulation supplies all the information needed to perform the analysis.
Reading data directly#
Output can also be analyzed without a simulation object. Give
analyze_output the RMG code name and its log-output path. An input object,
input-file path, or input directory can be supplied separately.
from nexus import analyze_output
ao = analyze_output(
'rmg',
input = './scf_run/input',
outfile = './scf_run/rmg.log',
)
The analyzer reads the selected RMG log. It can also locate and read the RMG control input named by the log when that file is available.
Accessing physical quantities#
The query methods return final values, rather than the histories printed during
iterative calculations. Scalar quantities are Python float or bool
objects; array quantities are NumPy float arrays; and structure queries
return Structure objects. Use the units argument where
applicable.
Supported run types and quantities#
The table lists data ordinarily produced by each major RMG run type. Actual
availability also depends on RMG printing options and successful parsing.
Here, common data means initial_structure, kpoints, and kweights;
electronic data means eigenvalues, occupations, Ef, Evbm,
Ecbm, band_gap, and fractional_occs.
Run type |
Quantities ordinarily available |
Not ordinarily applicable |
|---|---|---|
|
Common data, |
|
|
Common data, |
|
|
Common data and |
|
|
Common data, |
None of the listed query groups. |
|
Common data, |
None of the listed query groups. |
|
Data reported by the selected RMG mode. Electronic quantities are
available for |
|
Checking and requiring quantities#
Use available to check whether all named
quantities are accessible. It returns a single Boolean and does not initiate
additional parsing.
electronic_data = ao.available('Ef','eigenvalues','occupations')
print(electronic_data)
True
Use require when downstream work cannot
continue without a quantity. A later query for an unavailable required
quantity raises an exception rather than returning None.
print('Unavailable quantity:')
print('Energy =',[ao.energy()])
ao.require('energy','forces')
print('\nNow required:')
E = ao.energy()
Unavailable quantity:
Energy = [None]
Now required:
RuntimeError: required RMG quantity "energy" is not available
Common structure and k-point data#
initial_structure() returns a Structure with axes shaped (3, 3)
and pos shaped (natoms, 3). Its default length unit is Angstrom; use
units='B' for bohr.
structure = ao.initial_structure()
print('cell axes:')
print(structure.axes)
print('\natomic positions:')
print(structure.pos)
cell axes:
[[2.500 0.000 0.000]
[0.000 2.500 0.000]
[0.000 0.000 2.500]]
atomic positions:
[[0.000 0.000 0.000]
[1.250 1.250 1.250]]
kpoints() returns Cartesian reciprocal coordinates as a float array of
shape (nkpoints, 3). Its default unit is inverse bohr; use units='A'
for inverse Angstrom.
kpoints = ao.kpoints(units = 'A')
print(kpoints[:3])
[[ 0.000 0.000 0.000]
[ 0.628 0.000 0.000]
[ 0.000 0.628 0.000]]
kweights() returns the dimensionless integration weights as a float array
of shape (nkpoints,).
kweights = ao.kweights()
print(kweights)
[0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125]
Energy and electronic quantities#
energy() returns the final total energy as a Python float. The
default is Hartree; 'eV' and 'Ry' are also accepted.
energy = ao.energy(units = 'eV')
print(f'E = {energy:.3f} eV')
E = -129.342 eV
eigenvalues() returns a float array in eV by default, shaped
(nkpoints, nbands) for non-spin calculations or
(nkpoints, 2, nbands) for collinear spin calculations.
eigenvalues = ao.eigenvalues()
print(eigenvalues[0, :6])
[-15.382 -8.437 -1.928 2.714 6.183 9.762]
occupations() returns a dimensionless float array with the same shape as
eigenvalues().
occupations = ao.occupations()
print(occupations[0, :6])
[1.000 1.000 1.000 0.000 0.000 0.000]
Ef(), Evbm(), Ecbm(), and band_gap() return Python float
values in eV by default: the Fermi energy, valence maximum, conduction
minimum, and fundamental gap. Each accepts 'eV', 'Ha', or 'Ry'.
fermi_energy = ao.Ef()
vbm = ao.Evbm()
cbm = ao.Ecbm()
band_gap = ao.band_gap()
print(fermi_energy, vbm, cbm, band_gap)
5.931 4.802 6.427 1.625
fractional_occs() returns a Python bool indicating whether an
occupation is neither empty nor full within a default tolerance of 1e-3.
metallic = ao.fractional_occs(tol = 1e-4)
print(metallic)
False
Final structure, forces, and stress#
relaxed_structure() returns the final Structure for a relax or
neb calculation. Its axes and positions have the same shapes as the
initial structure.
relaxed_structure = ao.relaxed_structure(units = 'A')
print(relaxed_structure.pos)
[[0.000 0.000 0.000]
[1.247 1.247 1.247]]
forces() returns final Cartesian ionic forces as a float array of shape
(natoms, 3). The default unit is eV/Angstrom; 'Ry/B' and 'Ha/B'
are also accepted.
forces = ao.forces(units = 'eV/A')
print(forces)
[[-0.003 0.000 0.000]
[ 0.003 0.000 0.000]]
stress() returns the final stress tensor as a float array of shape
(3, 3). The default is GPa; it also accepts 'Pa', 'bar',
'kbar', 'Mbar', 'atm', 'eV/A^3', 'Ha/Bohr^3', and
'Ry/Bohr^3'.
stress = ao.stress(units = 'GPa')
print(stress)
[[ 0.010 0.000 0.000]
[ 0.000 0.012 0.000]
[ 0.000 0.000 0.014]]
pressure() returns the final hydrostatic pressure as a Python float.
It accepts the same units as stress() and uses GPa by default.
pressure = ao.pressure(units = 'GPa')
print(f'P = {pressure:.3f} GPa')
P = 0.012 GPa
Strict and permissive parsing#
RMG analysis reads one selected log-output file. It may be provided directly,
or discovered as the sole *.log file under path.
ao = analyze_output(
'rmg',
input = 'input',
outfile = 'rmg.log',
path = './scf_run',
strict = True,
)
With the default strict=True, an explicitly selected input or output must
exist, and output discovery must identify exactly one log. If the input and
log both identify a top-level run mode, they must agree. A disagreement raises
an exception under strict parsing.
Set strict=False to analyze an incomplete or missing log path without a
file error. The analyzer completes with no parsed physical data, and
applicable queries return None. Any data that is successfully parsed from
an existing log remains available.
ao = analyze_output(
'rmg',
outfile = './interrupted_scf/rmg.log',
strict = False,
)
As with PWSCF, required quantities can be supplied at construction or
added with require(). They do not trigger additional parsing for RMG; a
query for unavailable required data raises an exception.